What the buyer wrote
Based on the approximate site area on the attached plan, and taking into account our understanding of the ground investigation and remediation works completed to date, AECOM would recommend the following ground investigation scope of works: 1. 3 no. cable percussion boreholes to 10 m depth; to enable geotechnical data to be obtained to inform on preliminary foundation options and to facilitate the installation of groundwater monitoring wells; 2. 15-18 windowless sampling dynamic percussive boreholes to between 3 and 4 m depth; to provide sufficient sampling coverage across un-investigated areas of the site; 3. In-situ testing, field screening and subsequent accredited geochemical and geo…
Bid for this and lost? There is a short window in which the decision can be questioned.
Awarded to
Details
- What the buyer calls it
- Birmingham - Edgbaston - Intrusive SI's
- How they are buying
- The buyer did not say
- Type
- works
- Work starts
- 2 Jul 2015
- Work ends
- 31 Aug 2015
- Kind of work
- Building surveying and inspection
Who the buyer named
The buyer published a contact address on this notice.