THERMISTOR CABLES We require two cables, one 1400 m in length, the other 1500 m in length. 1. The cable will have a minimum of 26, multi-stranded copper conductors, each with a minimum cross sectional area 0.14 mm2. 2. The minimum voltage rating for the insulation will be 24 V. 3. The minimum current rating will be 100 mA. 4. The cable will have an aramid, central strain member. 5. The cable will have an outer jacket of polyurethane, with a minimum thickness of 1.4 mm. 6. The cable will be able to support all but 100 m of its own length in water (ie 1300 and 1400 m), 100 m of its own length in air, and a 100-kg ballast weight that will be suspended from the bottom end. 7. The cable w…