Skip to the main content
The Crier

Provision of VRV units Installation at Club Restaurant and Lounge at BHC Compound, New Delhi

Your saved contracts

What the buyer wrote

The work consists of the removal and disposal of the existing AHU, FCU and chilled water line from the complete roof of Lounge and club restaurant and installation and commissioning of the VRV, including the new wiring from DB board to VRV units including masonry work to make platform for installation of VRV units and making fence height up to 6' surrounding with heavy gauge steels bar distance of 4" each with 3 feet width lockable gate. Installation of new copper tubing from ground level to roof over the G.I casing capping with proper cover and make masonry stands as per standard distance to run the copper piping to install indoor units in the building .All the civil and electrical work un…

Read all of it on Contracts Finder →

Details

What the buyer calls it
Provision of VRV units Installation at Club Restaurant and Lounge at BHC Compound, New Delhi
How they are buying
Advertised, open to anyoneAny supplier could bid without being invited first.
Type
works
Suitable for small firms
The buyer says yes. What that is worth
Work starts
9 May 2018
Work ends
30 May 2018

Who the buyer named

Kathy Joslin was the named contact on this notice.